E-39 – Casio DT-900 User Manual

Page 37

Advertising
background image

E-39

1

RS-232C Interface

For connection to a PC and uploading/downloading of system data
and file data.

2

RS-422 Interface

For connection of multiple Optional Satellite Cradles.

3

AC adaptor jack

For connection of the AC adaptor to supply power.

4

Nose Guide

Remove this guide when you are using the down-facing reader port model.

5

Data Collector detection switch

Detects whether or not the Data Collector is mounted correctly on
the Satellite Cradle.

6

System operation indicator

Indicates whether or not system operation is normal.

A system operation problem is indicated when this indicator does not light up green shortly after the

Data Collector is mounted onto the Satellite Cradle.
Off:

All Data Collectors mounted on the Satellite Cradle are
unable to communicate, or there is a system problem.

Lit Green: Normal system operation. One or more of the Data

Collectors mounted on the Satellite Cradles are
communicating.

7

Data communication indicator

Indicates the status of data communication operations.
Off:

Not communicating

Flashing Green:

Communication in progress

Lit Red:

Optional Communication Unit
connection problem

8

Battery pack charge indicator

Indicates the charge status of the spare battery pack.
Off:

Not charging, or a battery pack problem

Lit Red:

Charging (charging standing by when the battery in the
Data Collector is charging)

Lit Green: Charging complete

9

Charge indicator

Indicates the charge status of the lithium-ion battery pack in the
Data Collector.
Off:

Not charging (e.g. lithium-ion battery not loaded in Data
Collector) or a battery pack problem

Lit Red:

Charging

Lit Green: Charging complete

10 Power indicator

Indicates whether power is ON or OFF, and if the Data Collector is
mounted.
Off:

Power OFF

Lit Red:

Power ON, Data Collector not mounted

Lit Green: Power ON, Data Collector mounted

11 Installation covers (L, R)

Hold down the charge/power supply terminals when the Satellite
Cradle is used as an installed type.

12 Charge/Power supply terminals Supplies power to the Data Collector mounted on the Satellite

Cradle.

13 Battery pack charge terminals

Charges the spare battery pack separately.

14 Infrared port

This port provides contact-less infrared communication capabilities
with a Data Collector.

15 Power switch

Turns power ON and OFF.

16 Base

Reverses the position of the base when wall-mounting the Satellite
Cradle.

17 DIP switches

Use these switches to set the operational configuration of the
Satellite Cradle.

18 Wall mounting hole

Use this hole to attach the Satellite Cradle to a hook on a wall.

Advertising