4 standby configuration (windows), 5 broadcast message configuration (windows), Standby configuration (windows) – Eaton Electrical V3 User Manual

Page 11: Broadcast message configuration (windows)

Advertising
background image


www.eaton.com





Network Shutdown Module V3 – User Manual - 34 003 934 XU / AE

Page 10/65

z

Mac Intel

Mac OS X 10.4, 10.5, 10.6

z

Mac PowerPC

Mac OS X 10.4, 10.5


2.2.1.4 Standby configuration (Windows):

In Configuration Panel -> Power Option properties:

z

You must unselect the Standby configuration of your Operating System to be compliant with the

Network Shutdown Module. With the standby configuration checked your system is not protected.

z

If you want to save energy, please prefer the hibernate feature.

2.2.1.5 Broadcast Message configuration (Windows):

If the “

Broadcast administrator messages / Broadcast user messages

” function is activated, on Network

Shutdown Module, you have to check that the “Messenger” Service is started.
This service is mandatory to use the broadcast messages on Windows.

2.2.1.6 Firewall configuration (Windows & Linux) and Gateway :

(Optional) To enable a remote access for supervision and configuration you will have to open the following
UDP and TCP ports of the Windows Firewall:

z

4679 EATON Supervision

z

4680 EATON Management (access through SSL)


These ports are reserved for EATON at IANA (Internet Assigned Numbers Authority, http://www.iana.org/).

If you use Windows, the ports are automatically opened in the Windows Firewall.

If you use a Firewall with all ports closed by default:
To enable communication between Network Shutdown Module and Network Management Card:

z

Port 80 must be opened as a destination port (for output) on the machine hosting Network Shutdown
Module.

If you use a Gateway without predefined routed port:
To enable communication between Network Shutdown Module and Network Management Card:

z

Ensure to route 4679 and 4680 ports with the protocol «TCP»&«UDP».

2.2.2 On the System that Displays Web-based Graphical User Interface

Important:

The Network Shutdown Module graphical interface can be accessed remotely using a simple Web browser.
Access to this interface is secured through SSL connection (default configuration) and must also be

secured

through Login & password

.


The Network Shutdown Module graphical interface has been tested with:

z

Mozilla Firefox (1.5, 2.0, 3.0) is recommended for better performance. (Firefox is mandatory for Linux)

z

Microsoft Internet Explorer V6, V7, V8

z

Safari


Note: For the Web browser, we advise you against the use of the highest security level. Some configuration
screens are not useable.
Javascript and Cookies must be authorized for the selected security level.