CrossPoint 450 Plus and MAV Plus Switchers • Installation

PRELIMINAR

Y

g

BME COMM interconnect ports

— If the matrix switcher system consists of

more than one BME, the BMEs must be connected together in a daisy chain
using Extron-supplied RJ-45 cables.

Connect the fi rst daisy chain from BME 0’s BME Comm Out connector to
the nearest BME’s BME Comm In connector (fi gure 2-9). In a rack where
BMEs are arranged so that their physical location matches the BME address
numbering, this would be BME 1. But since not all systems are confi gured
alike, call this module BME n.

64

63

62

61

LAN

ACT LINK

RESET

REMOTE

Rx

Tx

Rx

Tx

4

-

+

BME COMM

IN

OUT

BME

ADDRESS

EXT

SYNC

Rx

Tx

8

9

10

6

11

7

RESET

REMO

TE

Rx

Tx

LAN

AC

T

LIN

K

64

63

62

61

BME

COMM

OUT

BME

ADDRESS

EXT

SYNC

4

To BME

From BME

Figure 2-9 — Daisy-chaining BMEs (video BME shown)

Connect the next RJ-45 cable from BME n’s BME Comm Out connector to the
nearest unconnected BME’s (BME n+1’s) BME Comm In connector.

Continue connecting RJ-45 cables from each daisy-chained module’s BME
Comm Out connector to the next module’s BME Comm In connector until
all modules are included in the chain. When all of the BMEs are connected,
each of the BMEs in the system is connected to at least one other BME via the
BME Comm connectors.