Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional
description

View ties, gain, volume, mutes, presets, and DSVP (continued)

View audio global preset
confi guration

EX1!

*

X#

*2VC

}

X@

n

•X@

n+1

•X@

n+2

...

•X@

n+15

Aud

]

Show preset

X1!

’s audio

confi guration. Show the
audio input tied to 16
sequential outputs, starting
from output

X#

.

Command description:
Response description:

Preset# * starting output# (StO#) * 2(=audio) VC
Input# (I#) tied to StO#•I# tied to StO#+1•StO#+2•StO#+3• ... •StO#+15•Aud

]

Example:

E

4*17*2VC

}

01

Output:

Response = tied input:

input 1 tied to output 3

02 03 04 05 06 07 08 09 10 11 12

01•01•01•01•02•22•22•00•03•03•03•03•60•60•58•58•Aud

13 14 15 16

no tied input

input 58 tied to output 15

Each position show in the response is an output: left = starting, right = starting output+15. The number in each
position is the input tied to that output.
Audio — Input 1 is tied to outputs 1 through 4, input 2 is tied to output 5, input 3 is tied to outputs 9 through 12, and
input 22 is tied to outputs 6 and 7, input 58 is tied to outputs 15 and 16, input 60 is tied to outputs 13 and 14, and no
input is tied to output 8.

N

EX1!

*

X#

*2VC

}

where

X1!

= 0 returns the switcher’s current audio confi guration.

View video room preset
confi guration

EX*

*

X1@

*1*1VC

}

X@

n

•X@

n+1

•X@

n+2

...

•X@

n+15

Vid

]

Show room

X*

, preset

X1@

’s

video confi guration. Show
the video input tied to up to
16 outputs assigned to room

X*

.

Command description:

Room#* room preset#* starting output# (recommended value = 1) * 1(=video) VC

N

The matrix switcher responds to the View video room preset confi guration command with a series of responses,

each reporting the inputs tied to 16 outputs.

These responses should then be compared to a list of the outputs assigned to the specifi ed room to determine the ties in

the room preset.

For ease of understanding the starting output number should always be “1”.

Response description:

Input# (I#) tied to O#1

I# tied to O#2

O#3

O#4

... •O#16

Vid

]

Input# (I#) tied to O#17

I# tied to O#18

O#19

O#20

...

O#32

Vid

]

Input# (I#) tied to O#33

I# tied to O#34

O#35

O#36

...

O#48

Vid

]

Input# (I#) tied to O#49

I# tied to O#50

O#51

O#52

...

O#64

Vid

]