Replacement procedure, wiring & testing of parts – Equator MD3720CEE User Manual

Page 12

Advertising
background image

12

Replacement Procedure, Wiring & Testing of Parts



1) Power Switch (52799)


Replacement Procedure:

▪

Unplug the unit.

▪

Remove the top panel (Two screws behind and slide back)

▪

Pull out the soap dispenser, plastic washer knob and dryer knob.

▪

Remove the control panel. (3 Screws)

▪

Pull out the plastic switch cover for the power switch.

▪

Pull out the power switch by matching the grooves in the panel pushing the switch

towards the back.

▪

Replace with the new switch and do the wiring as before / below.

▪

Fix all the parts back by following the reverse procedure.


Wiring: Power switch - bottom view







Testing Procedure:

▪

Cold Test:

1) When the Power button is pushed in – There will be continuity between the connectors
1 & 3, 2 & 4.



112

114

111

113

1 2

4

3