Equator MD3720CEE User Manual

Page 13

Advertising
background image

13



2) Door Switch / Door Lock (00750)


Replacement Procedure:

▪

Unplug the unit.

▪

Open the door remove the clamp to the door gasket in the front to access the door

switch.

▪

Unscrew the two screws to the door switch.

▪

Replace with the new door switch and do the wiring as before / below.

▪

Fix all the parts back by following the reverse procedure.


Wiring: Door Switch – Back View










Testing Procedure:

▪

Cold Test:

1) Push the slider towards the left (referring to the position of the door switch as in the
figure) which will operate the micro switch and check for continuity between terminals 4 & 5.
2) If there is continuity door switch is good.

e

Please Note : The terminals 4 & 5 are not marked on the door switch it is just taken for

explanation.



1 2

3

Micro Switch

5

4

IPX

IP

MRL MRN

Latch / Slider

Advertising