PD8 Series Explosion-Proof Instrument Supplemental Manual

9

Product Ratings and Approvals;

FM

Enclosure: Type 4X; IP66
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III, Division 1, T5/T6
Class I, Zone 1, AEx d, IIC Gb T5/T6
Zone 21, AEx tb IIIC T90°C; Ta -40°C to +65°C
T6 Ta = -40°C to +60°C; T5 Ta = -40°C to +65°C
Certificate Number: 3047283

CSA

Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III, Division 1
Class I Zone 1 Ex d IIC
Zone 21 Ex tb IIIC T90°C
-40°C < Tamb. < +60° C; Temperature Code T6
-40°C < Tamb. < +65° C; Temperature Code T5
Enclosure Type 4X & IP66
Certificate Number: 2531731

ATEX

II 2 G D

Ex d IIC T* Gb
Ex tb IIIC T90°C Db IP68
Ta = -40°C to +*°C
*T6 = -40°C to +60°C
*T5 = -40°C to +65°C
Certificate number: Sira 12ATEX1182

IECEx

Ex d IIC T* Gb
Ex tb IIIC T90°C Db IP68
Ta = -40°C to +*°C
*T6 = -40°C to +60°C
*T5 = -40°C to +65°C
Certificate Number: IECEx SIR 12.0073

Special Conditions for Safe Use:
Use suitably certified and dimensioned cable entry device and/or plug. The
equipment shall be installed such that the supply cable is protected from mechanical
damage. The cable shall not be subjected to tension or torque. If the cable is to be
terminated within an explosive atmosphere, then appropriate protection of the free
end of the cable shall be provided. Cable must be suitable for 90°C.

Year of Construction
This information is contained within the serial number with the first four digits
representing the year and month in the YYMM format.

For European Community: The ProtEX-MAX must be installed in accordance with
the ATEX directive 94/9/EC, and the product certificate Sira 12ATEX1182.