Terminal blocks – RISCO Group Industrial LuNAR User Manual

Page 21

Advertising
background image

Ind. LuNAR RK200DTG3 Installation

Guide

19

Terminal Blocks

TERMINAL BLOCK 1 DESCRIPTION

+12V (RED)

Power supply positive (+) input voltage

- (BLK)

Common to control panel power supply

BUS (GRN)

Used for data communication with the ProSYS

BUS (YEL)

Used for data communication with the ProSYS

SET ∗

Used to remotely SET/UNSET the detector.
When an activation signal (see RC/SET Activation jumper for settings) is applied to the
SET input of the terminal block:

 AM will be disabled (if the AM DIP switch 5 was previously ON)

 MW module is enabled (if the Green Line DIP switch 3 was previously ON).
Removing an activation signal will cause a Self Test (if the Remote Self Test DIP switch
4 was previously OFF).

RC ∗

(REMOTE

CONTROL)

Used to enable/disable the remote control communication, only when DIP switch 7 is
“OFF”.
When an activation signal (see RC/SET input jumper for settings) is applied to the RC
input of the terminal block, Remote Control will be enabled.
Note: DIP switch 7 “ON” constantly enables RC communication.

WARNING:

Turn DIP switch 7 “OFF” after installation and when leaving the site for security
reasons. This will prevent unauthorized use of a remote control unit that may be used
to disable the detector.

Not relevant in BUS mode

TERMINAL BLOCK 2

DESCRIPTION

AM/FAULT

Normally closed output
The AM/FAULT output opens in the following events:

 Detector is masked (ALARM also opens in this case)

 Self Test failed

 Input voltage is low (6VDC-8VDC)

TAMPER

Normally closed output

ALARM

Normally closed output

Eng