Troubleshooting

This section describes possible system problems and their solutions:

Always perform the following preliminary checks before referring to the troubleshooting table:

Perform a complete visual inspection of the Ind. LuNAR RK200DTG3, for signs of mechanical
damage, loose connections or torn wires.

Check the connections of the incoming AC power source.

Trouble

Meaning

Response

ProSYS Configuration of
detectors fails/not accepted by
the system

ID configuration
problem

Disconnect all power sources,
configure the desired IDs and
reconnect power again

Tamper indication while working
in the BUS mode

Tamper
connection
malfunction

Verify that both DIP 8 and 9 are in
ON position

Tamper indication in the Relay
or BUS mode

Tamper probably
not closed

Visually verify that ceiling tamper
and spring are correctly installed

Walk test cannot be initiated via
the ProSYS keypad

Wrong code

Insert the appropriate code

Green LED doesn’t operate
during Walk test - MW channel
does not function

Ind. LuNAR
RK200DTG3 is
configured (via
the ProSYS) to
the “MW disable
on DISARM”
during ProSYS’s
DISARM mode

Normal behavior

Ind. LuNAR
RK200DTG3
operating in
Bypass mode
due to “Bypass
MW channel
mode”

Reset the detector.
If MW channel trouble reoccurs,
replace the detector with a new one