22

MULTISTATION INSTALLATION AND OPERATIONS MANUAL

e. If you are using model MLK-2U and can not access the computer from

the remote unit, check the power on the local unit or the bus cable is
disconnected. Check the status LEDs on the local and remote unit. If
they are not flashing at 1 second intervals, the bus cable may have a
problem.

5. Can’t access all functions of mouse

a. The Microsoft IntelliMouse or other similar wheel mice are not

supported at this time.

b. If Microsoft Ball Point mouse, get the latest mouse drivers.

6. Mouse does not move

a. MultiStation turned off after or not connected when the computer

booted or application that uses the mouse was run. Exit and re-enter
the application using the mouse or issue the reset command.

7. PS/2 mouse gets out of sync

a. Reset the mouse (Right Ctrl key + “R”)
b. Cabling was disturbed during mouse movement. Issue the null

command once or twice to re-sync the mouse.

8. Video fuzzy

a. Cable too long or wrong type. Verify that the resolution and distance

match the video distance table.

9. Video not synchronized or wrong color

a. Cable is loose, reseat cable
b. Wrong computer cable used.
c. Cable is defective, try using a cable from another computer
d. Port on MultiStation is defective, try using another port

10. Status LED flashes at a steady 3 second rate, Unit does not respond

a. Unit has a defective component and fails the self test. Unit must be

serviced.