Subaru Robin EX13 User Manual

Page 75

Advertising
background image

- 72 -

(1) Star

ter does not r

un or only

“clic

k”

sound is heard.

Problem and check item

Description

Remedy

1. Checking of

continuity of
wiring

Check S terminal and B terminal
for deformation, looseness,
rusting, or dust sticking.
Carefully check inserting
method of the S terminal.
If not abnormal, set the key
switch to START position while
cranking (no ignition of engine)
and check if voltage is applied
to the S terminal and B terminal
of starter motor.

(1) When no voltage is applied to the S

terminal and B terminal, check
continuity of the terminals and key
switch and repair or replace if
necessary.

(2) If voltage is applied to the S terminal

and B terminal, go to “2. Battery
checking.”

2. Battery checking Check battery voltage and specific

gravity of battery fluid.
[Voltage]
Normal value : 12.4 to 12.8V
Limit (charging required): 12.4V

or lower

Staring limit

: 12V (at 20 C)

[Specific gravity]
Normal value : 1.22 to 1.29

Limit (Charging required)

: 1.22 or lower

[Service life]
Variance in specific gravity
among cell

: 0.04 or more

3. Checking of

pinion operation

Check if the pinion operates or
sound of magnetic switch
contactor is heard.
If the pinion does not operate
or magnetic switch sound is not
heard, check continuity of each
coil of magnetic switch.

(1) If the pinion operates or contactor sound

is heard, step to “4. Checking of
magnetic switch (1).”

(2) In case of no continuity

Replace the magnetic switch.

(3) When continuity is OK

Step to “4. Checking of magnetic switch
(2).”

(1) Charge or change the battery when

voltage is lower than 12.4V or specific
gravity is lower than 1.22 (at 20 C).

(2) If the wiring and battery are normal,

remove the star ter and go to “3.
Checking of pinion operation.”

4. Checking of

magnetic
switch

(1) Operate the magnetic switch

and check B-M terminals

(2) Check the magnetic switch

plunger and bobbin interior for
dust sticking or rusting.

(1) In case of no continuity

Contact continuity failure. Replace the
magnetic switch.

(2) When continuity is OK

Step to “5. Motor checking.”

(1) Clean the plunger. If the bobbin interior

is contaminated, replace the magnetic
switch.

5. Motor checking

Connect the (+) side of the
batter y to the M terminal of
magnetic switch and check if the
motor runs.

(1) If the motor does not run, check electric

circuit inside the motor, field coil,
armature, and brush and replace faulty
parts.

BATTERY

GRAVITY METER

(+)

(-)

M

(+)

(-)

S

KEY SWITCH

B

K

M