TABLE 1-2. GENERAL SPECIFICATIONS

CHARACTERISTIC

REQUIREMENT

INPUT

A-c Voltage (User selectable)

105-125V/210-250V a-c

A-c Input Frequency Range

47-63 Hz

A-c Input Current

115V a-c
(nominal)

7.5 Amperes

230V a-c
(nominal)

3.7 Amperes

OUTPUT

Voltage/Current Adjustment
Range

0 - 100% of rating, either continuously (inherent resolution), by step or by programmed setting.

Remote Sensing Range

0.5V per lead

D-C Isolation Voltage

500V d-c

Enable/Disable Output Power

Using front panel or via the Digital Bus.

Polarity Reversal
(MR and MGR models only)

Built-in polarity reversal power & sense relays.

Protection

Overvoltage

Tracks programmed voltage, crowbars output & turns off input circuit
breaker.

Overcurrent

Tracks programmed current, crowbars output & turns off input circuit
breaker.

Overtemperature

Monitors heatsink temperature, crowbars output & turns off input circuit
breaker.

External Polarity
Reversal

Built-in diode protects unipolar supply output.

Power Loss

Detects loss of a-c input power, disables output & turns
off input circuit breaker.

Overvoltage or
interruption
between Power
and Sensing Leads

MR and MGR Models:

Output voltage and current programmed to zero
and output relays opened.

M and MG Models:

Output voltage and current programmed to zero
and/or output crowbar activated and input circuit
breaker turned off

CONTROL-INDICATORS

Programming Resolution/Accu-
racy

Programming Resolution

Accuracy

Voltage

0.024% EOMAX (12 Bits) 0.024% EOMAX

Current

0.024% IOMAX (12 Bits) 0.1% IOMAX

Data Read-back Accuracy

Voltage

0.1% EOMAX

Current

0.15% IOMAX

Output Display

2X16 Char. Alphanumeric LCD with LED Backlight Indicates Output Voltage, Output Current, Sta-
tus and Menu. Output voltage displayed by four digits with either three, two, or one decimal(s),
depending on Model; output current displayed by either three or four digits (depending on Model)
with two decimals.

Indicators (LED)

VOLTAGE MODE

Green; lit when unit is in voltage mode.

CURRENT MODE

Amber; lit when unit is in current mode.

POLARITY
REVERSED

Red; lit when polarity reversed. (Operational for MR and MGR Models only.)

REMOTE

Green; lit when unit is operating in remote mode.

OUTPUT
ENABLED

Green; lit when output is enabled.