5 preliminary operating procedures, 1 node address (channel number) selection, Table 2-3. node address selection – KEPCO MBT Series User Manual
Page 30: Preliminary operating procedures -6, Node address (channel number) selection -6, Node address selection -6

2-6
MBTSVC 111609
2.5
PRELIMINARY OPERATING PROCEDURES
After the unit is unpacked, and before the unit is installed, the following procedure is required to
set the node address.
2.5.1
NODE ADDRESS (CHANNEL NUMBER) SELECTION
The node address is set by Node Address selector DIP switch A3S1 accessed through the top
cover (see Figure 2-2). The address can be set to any number from 1 to 31 by setting the switch
positions to the binary value as shown in Table 2-3.
TABLE 2-3. NODE ADDRESS SELECTION
DECIMAL
ADDRESS
SELECTOR SWITCH SECTION
(SIGNAL LINE)
A3S1-4
(A4)
A3S1-3
(A3)
A3S1-2
(A2)
A3S1-1
(A1)
A3S1-0
(A0)
1
0
0
0
0
1
2
0
0
0
1
0
3
0
0
0
1
1
4
0
0
1
0
0
5
0
0
1
0
1
6
0
0
1
1
0
7
0
0
1
1
1
8
0
1
0
0
0
9
0
1
0
0
1
10
0
1
0
1
0
11
0
1
0
1
1
12
0
1
1
0
0
13
0
1
1
0
1
14
0
1
1
1
0
15
0
1
1
1
1
16
1
0
0
0
0
17
1
0
0
0
1
18
1
0
0
1
0
19
1
0
0
1
1
20
1
0
1
0
0
21
1
0
1
0
1
22
1
0
1
1
0
23
1
0
1
1
1
24
1
1
0
0
0
25
1
1
0
0
1
26
1
1
0
1
0
27
1
1
0
1
1
28
1
1
1
0
0
29
1
1
1
0
1
30
1
1
1
1
0
31
1
1
1
1
1