Amprobe IR-750 Infrared-Thermometer User Manual

Page 15

Advertising
background image

10

MAX, MIN, DIF, AVG

The thermometer can measure maximum (MAX), minimum (MIN), differential
(DIF) or average (AVG) temperatures each time a reading is taken. These values
are available for infrared measurements.

1. Press YELLOW button until MIN or MAX or AVG or DIF appears on the display

2. Pull and hold the trigger while aiming at the target surface.

3. The value will show on secondary display.

High Alarm (HAL) and Low Alarm (LAL)

The thermometer has a programmable high and low alarm to designate high
or low readings depending on the thresholds entered. When the alarm level is
reached, an alarm will sound. This feature is not available when measuring by
thermocouple.

To set either the high or low alarm:

1. Press YELLOW button to select HAL or LAL option.

2. Press

or

to adjust the threshold value.

3. Press SET button to complete the setting. Symbol

or

will

appear on the display.

To turn off the high or low alarm:

1. Press YELLOW button to select HAL or LAL option.

2. Press SET button. Disappearance of Symbol

or

on the display

indicates high or low alarm is off.

DATA Memory
The thermometer has 99 points data storage and the stored data can
be downloaded via IR-750 software. To save the data:

1. Press YELLOW button to select DATA option.

2. Press

or

to select data record number

3. Pull and hold the trigger while aiming at the target surface, press DATA

button to save the measurement value. You can also save the measurement
value within 8 seconds of display hold after releasing the trigger.

Advertising