Appendix b: error messages, Start-up error messages, Drive check error messages – Avago Technologies AcceleRAID 170LP User Manual

Page 49: Appendix b, Acceleraid 170lp error messages

Advertising
background image

Manual No. DB11-000024-00

B-1

Appendix B

AcceleRAID 170LP

Error Messages

Note

The firmware you are using may have these messages
turned off. However, they are listed here for your
reference.

Start-up Error Messages

The BIOS looks for any initialization message posted by the firmware during
the start-up sequence. If a message is found, one of the following errors
displays on screen and the installation process aborts.

AcceleRAID 160 fatal error--Memory test failed!

AcceleRAID 160 fatal error--Command interface test failed!

AcceleRAID 160 hardware error--Run Diagnostics to pinpoint

error

AcceleRAID 160 firmware checksum error--Reload firmware

Drive Check Error Messages

If the firmware finds a valid controller configuration, but it doesn't match the
SCSI drives currently installed, one or more of the following messages
display. Then, the BIOS prints out the following:

AcceleRAID 160 Configuration Checksum error--Run

configuration utility!

If the firmware detects that during the last power cycle the system was turned
off abruptly leaving some incomplete write operations, the following
message appears:

Recovery from mirror race in progress

WARNING: Dead SCSI devices (Channel Target) : x:y

The following messages may also appear:

AcceleRAID 160

cannot recover from Mirror Race!

Some system drives are inconsistent!

Advertising
This manual is related to the following products: