While IP Address be changed or forgotten admin

password –

To reset the IP address to the default IP Address “192.168.0.100” and the user
name / password to factory default mode (default user name and password is
admin).

Connect a serial cable to a COM port on a PC or notebook computer and to serial
(console) port of the Switch. The console port of the Switch is DCE already, so
that you can connect the console port directly through PC without the need of Null
Modem.

Figure 3. Console port connection of GSW-4804SF

A terminal program is required to make the software connection to the Switch.
Windows Hyper Terminal program may be a good choice. It can be accessed from
the Start menu. Click START, then Programs, Accessories and then Hyper Terminal.

MS-DOS based terminal program such as PC-PLUS, PROCOMM, can also make the
connection with the Switch built-in software. The COM port should be configured
as:

Baud: 9600

Parity: None

Data bits: 8

Stop bits: 1

Flow Control: None