1

DIP-1

DIP-2

DIP-3

DIP-4

Mode

Channel

Band Plan

SNR

OFF

CO

Interleave Symm

9dB

ON (default) CPE

Fast

Asymm

6dB

CO / CPE

u

CO (Central Office) – the Master device mode, usually
the CO device will be located at the data center of ISP or
enterprise to link to the backbone.

u

CPE (Customer Premises Equipment) – the Slave device
mode, usually the CPE device will be located at branch
office, home or remote side as the long reach data receiver.
The CPE can be connect to the PC, IP Camera or Wireless
Access Point and etc network devices.

Note

When the Ethernet Over VDSL2 Converter operate
at CPE mode, the DIP switch 2,3,4 is no function.

Fast and Interleave mode

u

Fast mode guarantees a minimum end to end latency less
than 1 ms.

u

Interleaved mode provides impulse noises protection for
any impulse noise with a duration less than 250 us. Inter-
leaved mode has a maximum end to end latency of 10m
sec.

Band Plan

u User has the ability to select Band Plan. When Symmetric

is selected that provides better downstream performance,
when Asymmetric is selected that provides better upstream
performance. Refer to table above for details.