ProSoft Technology AN-X-MOD User Manual

Page 23

Advertising
background image

AN-X-MOD (Master) Page

19

AN-X can generate a default ControlLogix data mapping configuration
based on the I/O it finds (see page 24). If you want AN-X to generate
the ControlLogix configuration, check Auto-configure S908 network and
ControlLogix configuration

. Otherwise, check Auto-configure S908

network

(the default).

Click the Auto-configure Network button.

AN-X sends messages to all possible drops and builds a configuration
based on the replies it receives. AN-X then displays the configuration it
found.

Example:

Drop=4,

,Rack=1,

,,Slot=1,Type=CPS_114_xx,;Addr=d4s1,Inp=00,Out=00,AC PS 115/230V 10A

,,Slot=2,Type=CRA_93x_00,;Addr=d4s2,Inp=00,Out=00,RIO DROP S908

,,Slot=3,Type=DDI_353_00,;Addr=d4s3,Inp=04,Out=00,DC IN 24V 4x8

,,Slot=4,Type=DDO_353_00,;Addr=d4s4,Inp=00,Out=04,DC OUT 24V 4x8