E

Controlling the Monitor with a PC (RS-232C)

Commands for setting of the GAMMA user data

Function

Command Direction

Parameter

Reply

Control/Response contents

*

RED GAMMA DATA TRANSFER

UGRW

W

aaxxxx ··· xxxxcc

(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF

aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data

GREEN GAMMA DATA TRANSFER

UGGW

W

BLUE GAMMA DATA TRANSFER

UGBW

W

RED GAMMA DATA READ

UGRR

W

1-16 xxxx ··· xxxx

(xxxx: 32 pieces)
xxxx: 0000-1023

xxxx: User data of 32 pieces

GREEN GAMMA DATA READ

UGGR

W

1-16

BLUE GAMMA DATA READ

UGBR

W

1-16

USER DATA INITIALIZE

UGRS

W

0

Initialize the user data.

USER DATA SAVE

UGSV

W

0

Save the user data in the monitor.