3 Wiring

E-17

Wire Size and Tightening Torque for Connectors

SERVOPACK

Model SGDV-

Terminal Symbol and Wire Size(mm

2

)

Ground Terminal

L1, L2, L3

/L1, L2

U, V, W L1C, L2C

/24V, 0V

B1/+, B2

Terminal

Screw

Size

Tightening

Torque

(N

x

m)

R70F

HIV

1.25

HIV

1.25

HIV

1.25

HIV

1.25

HIV2.0

or more

M4

1.2 to 1.4

R90F
2R1F

HIV

2.0

2R8F

R70A

HIV

1.25

HIV

1.25

HIV

1.25

HIV

1.25

HIV2.0

or more

M4

1.2 to 1.4

R90A
1R6A
2R8A

HIV

2.0

3R8A

HIV

2.0

5R5A
7R6A

120A

1R9D

HIV

1.25

HIV

1.25

HIV

1.25

HIV

1.25

HIV2.0

or more

M4

1.2 to 1.4

3R5D
5R4D

Advertising