5 compliance with ce marking, 1 installation conditions of emc directive – Yaskawa Sigma-5 Safety Precautions for SGDV Servo Amplifier User Manual

Page 23

Advertising
background image

5 Compliance with CE Marking

E-21

5 Compliance with CE Marking

5.1 Installation Conditions of EMC Directive

To adapt the EMC directives (EN55011 group1 classA, EN61800-3) for a
combination test using servomotors and SERVOPACKs from the

Σ

-V

series, a ferritic core, a noise filter, or a surge absorber must be used. For
details, read the Installation instructions in

Σ

-V series User’s Manual Setup

Rotational Motor

(SIEPS80000043) or

Σ

-V series User’s Manual Setup Lin-

ear Motor

(SIEPS80000044).

However, because this product is built-in, check that the following condi-
tions are still met after being installed in the final product.

5.2 Conditions Corresponding to Low Voltage Direc-

tive

To adapt SERVOPACKs to the Low Voltage Directive, make sure that the
following environmental conditions are met.

• Installation category: III
• Pollution degree: 2
• Protection class: 10
• Altitude: 1000 m max.

Be sure to install a fuse for the main circuit power-supply as well as meeting
these environmental conditions. To choose the fuse capacity, refer to 3.1
Model-case Circuit Breaker and Fuse Capacity.

Advertising