Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 403

Advertising
background image

376

Vess R2000 Series Product Manual

Promise Technologies

rc

Usage

rc [-a <action>] [-l <LdId>]

rc -a start -l <LdId> [-n] [-p]

rc -a stop -l <LdId>

rc -a pause -l <LdId>

rc -a resume -l <LdId>

Summary

The rc command starts, stops, pauses and resumes a Redundancy Check and monitors the

progress of a running Redundancy Check.

Options

-a <action>

Specifies action to perform.

list

(Default) Displays active and paused Redundancy Checks and

their status.

start

Starts a Redundancy Check.

stop

Stops a Redundancy Check.

pause

Pauses a Redundancy Check.

resume

Resumes a paused Redundancy Check.

-l <Ld ID>

Specifies the logical drive ID on which to run the Redundancy

Check.

-n

Do not fix inconsistent data. This option causes Redundancy

Check to run without correcting inconsistent data. All inconsistency

errors are reported.

-p

Pause on error. This option causes Redundancy Check to pause

when it encounters inconsistent data. The default is to continue on

error.

Advertising