Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 687

Advertising
background image

660

Vess

R2000

Series

Product

Manual

Promise

Technologies

Reported

Event

Corrective Action

RAID Level Migration

RAID level migration is started

No action is required.

RAID migration is in progress

RAID level migration is completed

RAID level migration is paused

Resume migration when ready.

RAID level migration is resumed

No action is required.

RAID level migration is stopped

If this action was not intentional, check the

logical drive’s status.

RAID level migration has encountered a

physical disk error

Check the disk drive check table after

migration and replace disk drive as

needed.

RAID level migration is aborted due to an

internal error.

Reduce system load on the Vess.

RAID level migration is queued

No action is required.

Migration has detected stale NV Watermark

Wait to see if the watermark clears.

Migration has cleared stale NV Watermark

No action is required.

Array was made incomplete due to missing

NV Watermark

If the array is online, try migration again. If

the array is offline, delete and recreate the

array.

User has accepted Incomplete Array. (Caused

by a missing NV Watermark)

Rebuild the disk array.