141

Codabar Start/Stop Characters

Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters.

Default

=

Don’t Trans-

mit

.

Codabar Check Character

Codabar check characters are created using different “modulos.” You can program
the scanner to read only Codabar barcodes with Modulo 16 check characters.

Default

=

No Check Character.

No Check Character

indicates that the scanner reads and transmits barcode data

with or without a check character.

When Check Character is set to

Validate and Transmit

, the scanner will only read

Codabar barcodes printed with a check character, and will transmit this character
at the end of the scanned data.

When Check Character is set to

Validate, but Don’t Transmit

, the unit will only

read Codabar barcodes printed

with

a check character, but will not transmit the

check character with the scanned data.

Off

Transmit

* Don’t Transmit

* No Check Character

Validate Modulo 16, but

Don’t Transmit

Validate Modulo 16

and Transmit