RIX LEAP L3 3.2-9.6x Thermal Imaging Riflescope User Manual

Page 16

Advertising
background image

• When Screen Freeze is selected, press the left button to freeze the screen;
• When Reticle Movement is selected, rotate the upper knob to move the reticle in the X direction, and rotate the right knob to
move the reticle in the Y direction;

• Once the reticle is calibrated, choose " Save" to save the calibration settings and exit directly. A prompt will

confirm the successful saving, and you will be returned to the home screen.
• When Exit without saving is selected, press the left button to exit without saving and return to the home screen;
• If you select "Delete," simply press the left button to delete the current group and return to the upper menu of the zeroing
interface. In the event that there is only one group remaining, a prompt will appear indicating that the deletion has been
canceled, stating: "There is only one group left. Delete operation canceled."

Shutter Correction Mode

Calibration is an effective solution for enhancing degraded or uneven images. By balancing the background temperature of
the detector, calibration can eliminate image defects and improve overall quality.

• In the Setting Menu, rotate the left knob to select Shutter Correction Mode;

• Rotate the upper knob to switch between Auto Calibration and Manual Calibration;
• When

14 ▶

Auto Calibration is selected, the device will automatically correct the shutter according to the software algorithm.

• When Manual Calibration is selected, on the home screen, press the up button to correct manually.