C. Diagnostics and Problem Solving

Diagnostic Question

Possible Causes of Condition

Solutions

Are the air controls open?

• No draft

• No combustion air

Open air controls

Is there enough paper?

Insufficient heat to ignite kindling

Use more paper

Is there enough kindling?

Is the kindling dry?

Insufficient heat to ignite fuel

Use drier kindling

Is there enough or too much wood?

Is it too large?

Is it dry enough?

• Insufficient heat to establish draft

• Insufficient air passage

• Insufficient surface area

• Ignition temperature high due to

moisture

Use small split wood that is well sea-

soned (split, covered on top minimum 6

months, preferably a year)

Are there adequate air spaces

between fuel pieces?

Insufficient combustion air and

exposed surface area

Arrange kindling and wood for air move-

ment

Is the chimney pre-warmed?

Exposed, cold chimney downdrafting

Use lighted rolled newspaper at flue

opening to start upward air movement

Is there smoke in the house?

• Obstruction in chimney

• Downdraft from chimney tem-

perature or from negative house

pressure

• Have chimney checked if it worked

previously

• Pre-warm chimney

• Shut off exhaust devices

• Open window slightly

Does the kindling wood not ignite?

Condition, amount, arrangement of

kindling and fuel

Use more, drier, well-spaced kindling

and fuel.

Does the kindling ignite, but the fuel

doesn’t?

• Amount of kindling

• Condition of fuel

• Use more kindling

• Use smaller, dry wood

Does the fuel ignite, but not burn well?

• Draft problem

• Condition of fuel

• Use well-seasoned wood and suf-

ficient amount

• Turn exhaust fans off

• Open window slightly

1. If I can’t get a good fire going, what am I doing wrong?

2. I smell smoke in the house after we have had a fire. What is the cause/what can I do?

Diagnostic Question

Possible Causes of Condition

Solutions

Is the chimney clean?

No: Creosote odor

Have chimney cleaned

3. I smell smoke in the house during operation. What is causing it?

Diagnostic Question

Possible Causes of Condition

Solutions

Do fires start and burn well?

No:

• Chimney obstruction

• Not enough kindling and/or fuel to

establish draft

• Inadequate combustion air

• Air controls not open

Yes:

Competition with exhaust devices

No:

• Check & clean chimney if needed

• Use adequate kindling & fuel

• Open air controls

• Open window

• Check for need for balanced air

make-up (Outside Air)

• Check door rope for seal.

Yes:

• Do not use exhaust fans during

startup

• Check for need for balanced air

make-up (Outside Air)