Heatilator • Constitution EPA Fireplace • 480-1091D

4/20/11

WARNING! Risk of Fire! You MUST maintain 2 in.

(51 mm) air space to insulation and other combustible

materials around the chimney system. Failure to do so

could cause overheating and fire.

The following steps should be skipped if using a

chase.

• Install roof flashing appropriate to roof pitch.

• Install round termination cap and storm collar.

• Nail the flashing to the roof. Keep gaps between the

flashing plate and the roof to a minimum.

• Caulk the flashing plate and roof junction as well as the

vertical seam on the flashing. All nail heads must be

caulked with a roofing sealant.

• Caulk the overlap seam of any exposed pipe sections

that are located above the roof line to prevent leaks.

Figure 8.12 Ceiling/Attic Construction

• Refer to Figure 8.11.

• Plumb from roof to center of chimney.

• Drive a nail up through roof to mark center of pipe.

• Measure to either side of nail and mark the 14-1/2 in. x

14-1/2 in. (368 mm x 368 mm) opening required.

• Measure opening on the horizontal; actual length may

be larger depending on roof pitch.

• Cut out and frame opening.

• Refer to

Chapter 25 of the Uniform Building Code for

roof framing details.

Continue assembling the chimney sections up through the

ceiling firestops as needed. While doing so, be aware of the

height and unsupported chimney length limitations given un-

der Section 8.A. Chimney Requirements.
Check each section by pulling up slightly from the top to en-

sure proper engagement before installing the succeeding

sections. If they have been connected correctly, they will not

disengage when tested.

I. Double-check the Chimney Assembly

J. Cut out Hole in Roof

K. Complete Installation

WARNING! Risk of Fire!

Secure offsets with screws (not to exceed 1/2in./13mm

in length).

Secure returns with strapping.

Straight chinney sections may be secured with screw

(not to exceed 1/2in./13mm in length) at the joints

Keep chimney sections from separating or twisting.

L. Install Flashing

Ceiling

Firestop

Straps

Optional

Additional

Support

Joint

Band

(Optional)

Figure 8.11 Secure the Chimney

• Assemble chimney so it passes through the framed

opening.

• Slip the flashing over the chimney.

NOTICE: Roofing shingles must be below the flashing

plate on the lower side of a sloped roof and over the

flashing plate on the sides and top.