Figure 3.1 IPI Pilot Flame Patterns

• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce

size is correct. See Service Parts List for proper orifi ce
sizing.

• Verify manifold and inlet pressures. Adjust regulator as

required.

• Inspect pilot fl ame pattern and strength. See Figure 3.1

for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.

• Inspect IPI fl ame-sensing rod for soot, corrosion and

deterioration. Polish with fi ne steel wool or replace as
required.

• Verify that there is not a short in fl ame sense circuit

by checking continuity between pilot hood and fl ame-
sensing rod. Replace pilot as necessary.

Light Bulb Maintenance

Frequency: As needed

By: Qualifi ed Service Technician

Tools needed: Protective gloves, replacement light bulbs.

• See Section 14.F.