44

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.

13

13

Finishing

Combustible Mantel Legs or Wall Projections

Non-Combustible Mantel Legs or Wall Projections

1 IN. MIN.

13 IN. MIN.

FROM OPENING

COMBUSTIBLE WALL OR

MANTEL LEG

FIREPLACE

OPENING

7 IN.

6 IN. MIN. FROM

OPENING

6 IN.
MAX.

COMBUSTIBLE

MATERIAL

Figure 13.3 Clearances to Combustible Mantel Legs or Wall

Projections.

1 IN. MIN.

13 IN. MIN.

4 IN. MAX.

FIREPLACE
OPENING

NON-COMBUSTIBLE WALL

NON-COMBUSTIBLE

MANTEL LEG

Figure 13.4 Clearances to Non-Combustible Mantel Legs or

Wall Projections.

Combustible Mantels

Non-combustible Mantels