Garden example - proposed installation – Husqvarna 230 ACX User Manual
Page 63
64 - English
7. GARDEN EXAMPLE - PROPOSED INSTALLATION
Area: 0.15 acre (600 m
2
). L-shaped garden
with the charging station placed in the narrow
area. There are two islands. No guide wire is
necessary.
Timer: Operating time of 8 hours per day.
Exit angles: Sector 1 70° - 130° and
Sector 2 250° - 290°. Proportion first 10 %.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide1, 4 minutes, Guide2, 4 minutes
and boundary wire 11 minutes.
Corridor width: 10
Area: 0.17 acre (700 m
2
). U-shaped garden
with the charging station placed on one of the
large open areas. Guide wire recommended
through the passage.
Timer: Operating time of 10 hours per day.
Exit angles: One sector 90° - 270°.
Follow loop out: Direction Guide 1, Distance
25 meters (80 ft) and Proportion 30 %.
Search method: Irregular and Follow guide
wire in.
Delay: Guide1, 3 minutes, Guide2, 4 minutes
and boundary wire 99 minutes. Automower™
is never permitted to follow the boundary
wire.
Corridor width: Guide1 3
Area: 0.20 acre (800 m
2
). Rectangular
garden with the charging station placed by an
island. A large part of the boundary wire is
routed on a slope that is steeper than 10 %.
Guide wire recommended.
Timer: Operating time of 10 hours per day.
Exit angles: One sector 90° - 270°.
Search method: Irregular and Follow guide
wire in.
Delay: Guide1, 4 minutes, Guide2, 4 minutes
and boundary wire 99 minutes. Automower™
is never permitted to follow the boundary
wire.
Corridor width: Guide1 20
Proposals for installation and settings