7. GARDEN EXAMPLE - PROPOSED INSTALLATION

This example only applies to 230 ACX.

Area: 0.75 acre (3000 m

2

). Two guide wires

are recommended.

Timer: Operating time of 24 hours per day.

Exit angles: One sector 90° - 270°.

Follow loop out: Area 1; Direction Guide 1,
Distance
130 ft (40 meters)) and Proportion
20 %.
Area 2; Direction Guide 2, Distance
100 ft (30 metres)) and Proportion 40 %.

Search method: Irregular, Follow guide wire
in and Follow boundary wire in.

Delay: Guide1, 2 minutes, Guide2, 2 minutes
and boundary wire 11 minutes.

Corridor width: Guide1 8, Guide2 8,
and boundary wire 8.

Proposals for installation and settings