6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 97

Screen display

Reference

(1) In case of selecting the " SERVICE"[PF1] → 1.Monitering → 19.Analog data,

you can do the monitoring on the input/output state of analog input/output signal.

(2) The speed proportion output data is taken in custody in the control constant file.

(ROBOT.C00)

(3) It can't be changed in case that the control constant file(ROBOT.C00) is completely

protected.

Terminal name

Pin number

Signal

1

Channel 0 output

2

AGND (Analog ground)

3

Channel 1 output

4

AGND (Analog ground)

5

Channel 2 output

6

AGND (Analog ground)

7

Channel 3 output

TBA0

8

AGND (Analog ground)

14:39:38 ** Speed by voltage ** A:0 S:4


Minimum voltage = [

-3.7

] (V)

Maximum voltage = [ -0.2] (V)
Minimum speed = [3368.0] (mm/sec)
Maximum speed = [6524.0] (mm/sec)
Port No. = [ 160] 0=>No output

Select and Enter number. Press [SET]

>[-12.0 - 12.0]