Accuracy calibration – HP 220 User Manual

Page 144

Advertising
background image

7Ć6 Calibrations

C3187Ć90000

Accuracy Calibration

Purpose

The accuracy calibration procedure is used to correct the endĆpoint accuracy of the media

axis. The cartridge axis does not require calibration and is used to calibrate the media axis.
Perform the accuracy calibration whenever the:

D EEROM is erased
D Main PCA is replaced
D Drive roller is removed or replaced
D Media (XĆaxis) motor is replaced

What is the EndĆPoint Accuracy Specification ?

The endĆpoint accuracy specifies how accurately a plotter can draw a given length of line.

The endĆpoint accuracy specification for the plotters is

±

0.38 mm (0.015 in) or

±

0.2% of the

specified vector length, whichever is greater, at 23

d

C (73

d

F), at 50Ć60% relative humidity on

HP special polyester film. Use the following formula to calculate the plotter's accuracy:

Measured length – Desired length

Desired length

x 100 = %Error

What can Affect the EndĆPoint Accuracy ?

Various part tolerances inside the plotter affect the accuracy (in particular the drive roller).

Other outside influences include:

D Mediathickness. Thicker mediacreates longer lines.
D Mediaexpansion. As the mediagrows, so do the lines.
D Application software. The software may be instructing the plotter to draw an incorrect

line length.

D The EEROM has been cleared. The accuracy constants are stored in this nonĆvolatile

memory component.

(Further information D chapter 5, w MediaĆDrive Accuracy.)

Advertising
This manual is related to the following products:

200