Bail calibration – HP 220 User Manual

Page 146

Advertising
background image

SHIFT

Accuracy
Calib. Read

ALT

Bail Calibration

7Ć8 Calibrations

C3187Ć90000

,0 When the

Ready

LED lights up, holddown the

SHIFT

key andpress

Accuracy Calib. Read,

The

Busy

LED lights up. The plotter takes about

3 minutes to read the calibration sheet, to calculate

the calibration data, and to save the data in the

EEROM. During this time, the plotter appears

almost motionless for short intervals. The plotter

then ejects the sheet.

,, Unloadthe sheet.

Bail Calibration

In this procedure, the `up' position of the bail assembly is calibrated. A value is stored in the

EEROM when the procedure is completed.
Perform the bail calibration whenever the:

D EEROM is cleared
D Main PCA is replaced
D Bail falls during media loading
D Bail switch is replaced
D BailĆlift mechanism is removedor replaced

To calibrate the bail, perform the following procedure:

, Enter service mode D page 7Ć2.
. Holddown the ALT key andpress Bail Calibration.

The Busy LED lights up and the bail begins cycles of being raised and lowered.

During a number of the cycles, the bail is let fall instead of being gently lowered.

The calibration ends after about a minute and a half.