Performing the accuracy calibration – HP 220 User Manual

Page 145

Advertising
background image

SHIFT

Accuracy
Calib. Print

7Ć7

Calibrations

C3187Ć90000

Performing the Accuracy Calibration

, Enter service mode D page 7Ć2.
. Plot a service configuration plot D page 8Ć23.
A Measure the distance between the centers of the X" marks on the configuration plot.

An accuracy calibration is needed if this distance is not

500 mm (20 in) 1 mm (0.04 in) under normal environmental conditions.
If the measured accuracy, media thickness, or environmental conditions vary greatly from

the factory standards, recalibrate the plotter by continuing with the following steps.

4 Place a sheet of media (preferably inkjet polyester film) over the top of the plotter for 10

minutes to let the sheet stabilize to the environmental conditions.
Use a sheet approximately 61 x 91 cm 24 x 36 in .

5 Select the appropriate

Media Type

on the front panel.

6 Loadthe media in portrait orientation into the plotter.

If using inkjet polyester film, load the film with the matte dull side down.

7 When the

Ready

LED lights up, holddown the

SHIFT

key andpress

Accuracy Calib. Print.

The Busy LED lights up and the plotter plots a

calibration plot. The plotter ejects the sheet,

and the

Load Media

LED lights up.

8 Unloadthe sheet.
9 Reloadthe sheet facedown into the plotter, in the direction indicated by the arrows on

the calibration plot.
If the plotter is D/A1 size, the sheet does not fit in the entry slot in the orientation

indicated by the arrows. In this case, cut the blankend off the media so that it fits.

Cut along the long line on the plot; the cut must be very straight so that the sheet can

be loaded.

For D/A1-size plotters,
cut along this line

Advertising
This manual is related to the following products:

200