Honeywell HCE 60 User Manual

Page 48

Advertising
background image

Appendix

46

Help with problems

Problem

Cause/Solution

LED does not
illuminate when power
plug is plugged in.

Mains voltage not connected.

►

Check voltage of electrical outlet.

►

Check fuse at storey controller.

LEDs 1 through 8 of
the zones do not
illuminate red continu-
ously during start-up.

The setpoint adjuster cannot be assigned.

►

Check whether batteries in setpoint ad-
juster are inserted properly.

►

Check wireless connection.

LEDs 1 through 8 of
the zones do not
illuminate green con-
tinuously during start-
up.

The room name cannot be assigned.

►

Check whether Hometronic Manager is
installed.

►

Check whether or not a room name is
assigned to zone.

►

Reassign zone if applicable.

Not all rooms are
warmed/cooled.

►

Check heating and inlet temperature.

►

Check adaptation to thermal actuator (see
Page 15).

►

Check fuse of storey controller.

If fuse is defective:

►

Check actuators for short circuit.