3. On water-cooled model only, first remove the water from the water-cooled

condenser:

1) Make sure the power supply is off, then remove the front and right side panels.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop

system, also close the condenser return line shut-off valve.

3) Open the condenser water supply line drain valve. If connected to a closed loop

system, also open the condenser return line drain valve.

4) Attach a compressed air or carbon dioxide supply to the condenser water supply line

drain valve.

5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer

underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.

6) Close the drain valve(s).
7) Replace the right side panel and front panel in their correct positions.