Fig. 6 – Hoshizaki FD-1001MWH(-C) EN User Manual

Page 65

Advertising
background image

65

Drain Valve
#10 (white/blue)

K6 Connector (20VDC)

Infrared Sensor

"SERVICE" Button

(Ice Purge Cycle Bypass)

Transformer
24VAC Input
#1 (white/red)

Upper Float Switch
#6 (red)
Open-5VDC to #5 black
Closed-0VDC to #5 black

Mechanical Bin Control
#3 to #4 (gray)
Open-5VDC
Closed-0VDC

Gear Motor Protect Relay Circuit
#5 to #6 (white/orange)
Relay De-Energized-Open-5VDC
Relay Energized-Closed-0VDC

High Pressure Switch
#3 to #4 (yellow)
Open-5VDC
Closed-0VDC

Control Switch
#1 to #2 (white/black)
"ICE"-Open-5VDC
"DRAIN"-Closed-0VDC

"POWER OK" LED

Transformer
24VAC Neutral
#2 (light blue)

Lower Float Switch
#7 (dark blue)
Open-5VDC to #5 black
Closed-0VDC to #5 black

Float Switch
#5 (black)

S1 Dip Switch

K9 Connector

K8 Connector

(24VAC and 5VDC)

K7 Connector-open

K2 Connector

(24VAC)

Fig. 6

Open
(yellow LED flashing
or steady)
20VDC DBU to BR
0VDC DBU to W
20VDC W to BR

Closed
(yellow LED off)
20VDC DBU to BR
20VDC DBU to W
0VDC W to BR

Brown
(BR)

Dark Blue
(DBU)

White
(W)

5VDC common terminals

K1 Connector

(115VAC)
#3 Input (black)
#2 GM, FMR,
FMS (brown)

Inlet Water Valve
#8 (white/brown)

Transformer
Input
#9 (white/red)

Transformer
Input
#7 (white/red)

Advertising