Fd-1001mrh-c (remote air-cooled) – Hoshizaki FD-1001MWH(-C) EN User Manual

Page 55

Advertising
background image

55

APPROXIMATE

Ambient

Water Temp. (°F)

ICE PRODUCTION

Temp. (°F)

PER 24 HR.

70

*930

*(423)

895

(406)

860

(390)

80

825

(375)

790

(360)

760

(345)

90

730

(332)

*720 *(326)

670

(306)

lbs./day (kg/day)

100

645

(294)

620

(282)

*580 *(263)

APPROXIMATE ELECTRIC

70

*1401

--

1408

--

1415

--

CONSUMPTION

80

1422

--

1428

--

1435

--

90

1442

--

*1449

--

1444

--

watts

100

1440

--

1435

--

*1430

--

APPROXIMATE WATER

70

*112 *(423)

108

(406)

103

(390)

CONSUMPTION PER 24 HR.

80

99

(375)

95

(360)

91

(345)

90

88

(332)

*86

*(326)

81

(306)

gal./day (l/day)

100

78

(294)

75

(282)

*70

*(263)

EVAPORATOR OUTLET TEMP.

70

*5

*(-15)

5

(-15)

5

(-15)

80

5

(-15)

9

(-13)

9

(-13)

90

9

(-13)

*9

*(-13)

12

(-11)

°F (°C)

100

12

(-11)

12

(-11)

*12

*(-11)

HEAD PRESSURE

70

*205 *(14.4)

205

(14.4)

205

(14.4)

80

234

(16.5)

234

(16.5)

234

(16.5)

90

264

(18.6)

*264 *(18.6)

264

(18.6)

PSIG (kg/cm²G)

100

301

(21.1)

301

(21.1)

301

*(21.1)

SUCTION PRESSURE

70

*33

*(2.3)

33

(2.3)

33

(2.3)

80

35

(2.4)

35

(2.4)

35

(2.4)

90

36

(2.6)

*36

*(2.6)

36

(2.6)

PSIG ( kg/cm²G )

100

39

(2.7)

39

(2.7)

*39

*(2.7)

CONDENSER VOLUME

74.5 cu in

HEAT OF REJECTION FROM CONDENSER 8900 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR 1400 BTU/h (AT 90°F /WT 70°F)

50

70

90

Note: We reserve the right to make changes in specifications and design without prior

notice.

6. FD-1001MRH-C (remote air-cooled)