Hoshizaki FD-1001MWH(-C) EN User Manual

Page 72

Advertising
background image

72

Problem

Possible Cause

Remedy

[1] The icemaker will not

start (continued).

i) High Pressure Switch

(continued)

7. Condenser water

pressure too low or off
(water-cooled model).

7. Check and get

recommended pressure.

8. Water regulating

valve set too high
(water-cooled model).

8. Adjust it lower.

j) Control Switch

1. "DRAIN" position.

1. Move to "ICE" position.

2. Bad contacts.

2. Check for continuity and

replace.

k) Inlet Water Valve

1. Coil winding opened.

1. Replace.

l) Control Board

1. Defective.

1. See "IV.B. Diagnostic

Procedure."

[2] Fill cycle will not

terminate.

a) Float Switch

1. Bad contacts.

1. Check for continuity and

replace.

2. Float does not move

freely.

2. Clean or replace.

b) Drain Water Valve

1. Valve seat clogged

and water leaking.

1. Clean or replace.

c) Hoses

1. Disconnected.

1. Connect.

d) Control Board

1. Defective.

1. See "IV.B. Diagnostic

Procedure."

[3] Ice purge cycle will

not start.

a) Control Board

1. Defective.

1. See "IV.B. Diagnostic

Procedure."

b) Gear Motor Fuse

1. Blown.

1. Check gear motor

amperage, bearing wear
(see "V.D.1. Upper Bearing
Wear Check"), supply
voltage.

c) Gear Motor Thermal

Protector

1. Open.

1. Check gear motor bearings,

voltage supply.

d) Gear Motor Protect

Relay

1. Open windings.

1. Replace.

2. Open or stuck

contacts.

2. Replace.

e) Gear Motor

1. Open windings.

1. Replace.

2. Auger coupling broke. 2. Replace.
3. Locked bearings.

3. Replace.

[4] Freeze cycle will not

start (compressor).

a) Control Board

1. Defective.

1. See "IV.B. Diagnostic

Procedure."

b) Starter (start relay)

1. Bad contacts.

1. Check for continuity and

replace.

2. Coil winding opened.

2. Replace.

3. Loose connections.

3. Tighten.

c) Start Capacitor or Run

Capacitor

1. Defective, weak.

1. Replace.

Advertising
This manual is related to the following products: