F. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

Remedy

[1] The icemaker will not

start.

a) Power Supply

1. Off, blown fuse, or

tripped breaker.

1. Turn on, replace, or reset.

2. Loose connection.

2. Tighten.

3. Bad contacts.

3. Check for continuity and

replace.

4. Not within

specifications.

4. Refer to nameplate and

correct.

b) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

c) Power Switch

(Control Box)

1. "OFF" position.

1. Move to "ON" position.

2. Bad contacts.

2. Check for continuity and

replace.

d) Circuit Protect Relay

1. Power supply not

within specifications.

1. Refer to nameplate and

correct or re-wire.

2. Bad Contacts.

2. Check for continuity and

replace.

e) Transformer

1. Coil winding opened.

1. Replace.

f) Fuse (Control Box)

1. Blown.

1. Check for short circuit and

replace.

g) Infrared Sensor

1. No power or defective. 1. See "IV.D. Bin Control

Check."

h) Mechanical Bin

Control (Backup Bin
Control Safety)

1. Tripped with bin filled

with ice. (9-beep
alarm)

1. Remove ice.

2. Mechanical bin control

stuck open.

2. See "IV.D. Bin Control

Check."

3. Actuator paddle does

not move freely.

3. Clean shaft and its

corresponding holes
or replace damaged
components.

i) High Pressure Switch 1. Bad Contacts.

1. Check for continuity and

replace.

2. Dirty air filter or

condenser.

2. Clean.

3. Ambient or condenser

water temperature too
warm.

3. Reduce temperature.

4. Refrigerant

overcharged.

4. Recharge.

5. Fan not operating

(except water-cooled
model).

5. See chart "3.[2.]a) Fan

Motor"

6. Refrigerant line or

component restricted.

6. Remove the restriction or

component and replace the
drier.