Note: We reserve the right to make changes in specifications and design without prior

notice.

2. FD-1001MAH-C (air-cooled)

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with neutral for 115V)

COMPRESSOR

240 V

4.2 RLA

34 LRA

GEAR MOTOR

120 V

3 FLA

1/4 HP

FAN MOTOR

115 V

0.85FLA

1/15 HP

OTHER

120 V

0.03A

MAXIMUM FUSE SIZE

15 A

MAX. HACR BREAKER (USA ONLY)

15 A

MAX. CIRC. BREAKER (CANADA ONLY)

15 A

MINIMUM CIRCUIT AMPACITY

15 A

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

50

70

90

lbs./day ( kg/day )

70

*940 (427)

890 (405)

855 (389)

Reference without *marks

80

820 (373)

790 (358)

755 (344)

90

725 (330)

*695 (317)

670 (304)

100

640 (292)

615 (280)

*580 (265)

SHAPE OF ICE

Cubelet

ICE QUALITY

Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

N/A

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

ELECTRIC W (kWH/100 lbs.)

1390 (4.8)

1320 (3.4)

POTABLE WATER

86 (12)

113 (12)

gal./24HR (gal./100 lbs.)

EXTERIOR DIMENSIONS (WxDxH)

22" x 24" x 25-15/16" (560 x 610 x 658mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

WEIGHT

Net 176 lbs. ( 80 kg ), Shipping 205 lbs. ( 93 kg )

CONNECTIONS - ELECTRIC

Permanent - Connection

- WATER SUPPLY

Inlet 1/2" FPT

- DRAIN

Outlet 3/4" FPT

ICE MAKING SYSTEM

Auger type

HARVESTING SYSTEM

Direct Driven Auger ( 1/4 HP Gear Motor )

ICE MAKING WATER CONTROL

Float Switch

COOLING WATER CONTROL

N/A

BIN CONTROL SYSTEM (PRIMARY)

Photoelectric Sensor

BIN CONTROL SYSTEM (SECONDARY)

Mechanical Bin Control (Proximity Sw.)

COMPRESSOR

Hermetic, Model RS70-C1E-PFV

CONDENSER

Air-cooled, Fin and tube type

EVAPORATOR

Copper Tube on Cylinder

REFRIGERANT CONTROL

Thermostatic Expansion Valve

REFRIGERANT CHARGE

R-404A,

1 lb.12oz.

(800g)

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-off Relay

COMPRESSOR PROTECTION

Internal Protector

GEAR MOTOR PROTECTION

Fuse (3A)

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW WATER PROTECTION

Float Switch and Timer

ACCESSORIES -SUPPLIED

Spare Fuse

-REQUIRED

Ice Storage Bin

OPERATING CONDITIONS

VOLTAGE RANGE

187-253 V

AMBIENT TEMP.

45-100° F

WATER SUPPLY TEMP.

45-90° F

WATER SUPPLY PRESSURE

10-113 PSIG