9) Remove the object covering the infrared sensor. If you removed the infrared sensor

housing from the base, replace it in its correct position, and secure it with the
thumbscrew.

10) Move the power switch to the "OFF" position. Turn off the power supply, then proceed

to "IV.D.2. Mechanical Bin Control Check."

2. Mechanical Bin Control Check

When the actuator paddle is not engaged the mechanical bin control is closed and the
icemaker produces ice.
a) Backup Bin Control: S1 dip switch 7 placed in the "ON" position, the mechanical bin
control is used as a backup bin control safety. When ice fills the chute and engages the
actuator paddle, the mechanical bin control opens and the control board shuts down the
icemaker within 10 seconds and sounds a 9-beep alarm.
b) Stand-Alone Bin Control: S1 dip switch 7 placed in the "OFF" position, the
mechanical bin control is used as a stand-alone bin control. The stand-alone application
should only be used in Hoshizaki standard ice storage bin applications. When ice fills
the chute and engages the actuator paddle, the mechanical bin control opens and the
control board shuts down the icemaker within 10 seconds.

WARNING! Do not place

S1 dip switch 7 in the "OFF" position on dispenser unit applications. See "II.C.4.a)
Default Dip Switch Settings."

1) Make sure the power supply is off.
2) Remove the strap connecting the spout to the chute assembly. See Fig. 8. Pull up the

chute assembly slightly so that you can access the actuator paddle located in the top of
the chute.

3) Move the power switch to the "ON" position.
4) Turn on the power supply to start the automatic icemaking process.

Infrared Sensor

Infrared Sensor
Housing

Lens

Infrared Sensor LED

Infrared Sensor LED

Fig. 7

Thumbscrew

Fig. 8

Chute Assembly

Actuator Paddle

Spout

Strap

Proximity Switch

Strap

Advertising