Caution, Electrical information, A. ignition system wiring – Heat & Glo Fireplace AUSTRALIAN GAS ASSOCIATION DAKOTA-AU User Manual

Page 10: B. remote control

Advertising
background image

10

Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07

Battery polarity must be correct or module damage will
occur.

CAUTION

6

6

Electrical Information

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

BATTERY PORT

(4 AA BATTERIES)

VALVE

PILOT

IGNITION MODULE

6VDC

ON/OFF

SWITCH

THERMOCOUPLE

BLOCK

(CONNECTED TO
BACK OF VALVE)

PILOT GAS LINE

CONNECTED TO

BACK OF VALVE

IGNITION

MODULE

(6V)

ON/OFF

WALL SWITCH

VALVE

FLAME SPARKER/

SENSOR

ANT.

REMOTE

CONTROL

A. Ignition System Wiring

• This

fi replace is equipped with an electronic ignition

system which operates on a 6 volt system.

• The batteries are located within the ignition module which

is located within the external control box. A wiring diagram
is shown in Figure 6.1.

• The battery pack requires four AA batteries (not included).

See Section 10.B. for battery replacement.

Figure 6.1 Electronic Ignition Wiring Diagram

B. Remote Control

• This fi replace is equipped with a remote control to

operate the ignition system.

• 9 volt battery required.
• Follow operating instructions included with remote

control.

Advertising