A. valve access and service – Heat & Glo Fireplace AUSTRALIAN GAS ASSOCIATION DAKOTA-AU User Manual

Page 21

Advertising
background image

Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07

21

A. Valve Access and Service

Figure 10.1 Lift Out Doors

Figure 10.3 Loosen Refractory Retaining Strip

Figure 10.4 Remove Valve Access Panel

Figure 10.5 Remove Exterior Valve Access Panel

Figure 10.6 Connect Manometer

• The gas valve can be accessed behind the cement

refractory panel on the right side of the fi replace.

• Remove door lock screw. Lift doors out and set aside.

There is a washer under each door. Be careful not to lose
the washers.

• Use a phillips screwdriver to remove the exterior valve

access panel (remove four screws).

• Loosen lower pressure tap screw before attaching

manometer. Start up the fi replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.

Note: Pressure tap screws must be re-tightened.

• Remove logs if access is necessary after installation is

complete. See Section 8.C. Remove logs in reverse order
of set up.

• Remove grate if access is necessary after installation is

complete. (Refer to Section 8.B.)

• Remove two screws on side of pilot shield and remove

shield.

• Remove the inside valve access panel by lifting it up and

out.

Figure 10.2 Remove Pilot Shield

• Use a phillips screwdriver to remove the two screws

securing the refractory retaining strip. Remove the
refractory side panel and set aside.

WASHER

WASHER

Advertising