Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07

Sealant Material

0 mm.

0 mm.

0 mm.

Finish wall material
may be combustible,
top & sides.

Upper front can be covered
with non-combustible material
or removed and replaced with
non-combustible material.

Fire Risk
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause

temperature rise and fi re hazard.

Finishing materials must not interfere with:
• Air

fl ow through grilles or louvers.

• Operation of louvers or doors.
• Access for service.

WARNING

B. Facing Material

Figure 7.2 Non-combustible Facing Diagram

Fire Risk
Finish all edges and fronts to clearances and
specifi cations listed in manual.

WARNING

• Metal fireplace front may be covered with non-

combustible material only.

• Do NOT overlap combustible materials onto fi replace

front.

• Install combustible materials up to specifi ed clearances

on top front and side edges.

• Seal joints between the fi nished wall and fi replace top

and sides using only a 150° C minimum sealant.