C. outdoor enclosure options – Heat & Glo Fireplace AUSTRALIAN GAS ASSOCIATION DAKOTA-AU User Manual

Page 7

Advertising
background image

Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07

7

An enclosure with walls on all sides, but at least one permanent
opening at ground level and no overhead cover.

Figure 3.3 Four Sides and a Permanent Opening

C. Outdoor Enclosure Options

Any enclosure in which the appliance is used shall comply
with one of the following (Figures 3.3 - 3.7):

A partial enclosure that includes an overhead cover
and no more than two walls.

Figure 3.4 Two Walls and a Roof

Both ends open

A partial enclosure that includes an overhead cover
and no more than two walls.

Figure 3.5 Two Walls and a Roof

Open side at
least 25% of
total wall area

30% or more in total
of the remaining wall
area is open and
unrestricted

Figure 3.6 More than Two Walls

With an overhead cover and more than two walls, the follow-
ing shall apply (Figures 3.6 - 3.7):

• At least 25% of the total wall area is completely open,

and

• At least 30% of the remaining wall area is open and

unrestricted.

• In the case of balconies, at least 20% of the total wall area

shall be, and will remain, open.

Open side at
least 25% of
total wall area

30% or more in total
of the remaining wall
area is open and
unrestricted

Figure 3.7 More than Two Walls