2 pkw-part, Chapter5 operating – Hitachi SJ-PB(T) User Manual

Page 15

Advertising
background image

CHAPTER5 OPERATING

11

5.2 PKW-part

The parameter part (PKW) is fixed to 4 words and can be used for reading and/or updating the parameters in the
inverter one by one. Requests and responses is a handshake procedure and cannot be batched, meaning that if
the master sends out a read/write request, it has to wait for the response, before it sends a new request.
The PKW is further divided into three parts; PKE- Parameter ID (2 bytes), IND – Sub-index (2 bytes) and PWE-
Parameter value (4 bytes).

PKW

PZD

PKE

IND

PWE

PZD1

STW
ZSW

PZD2

HSW

HIW

PCD3

PCD4

PCD5

PCD6

PCD7

PCD8

PCD9

PCD10

PKW: Parameter ID/value.
PKE: Parameter ID.
IND: Sub-index (3

rd

byte, 4

th

byte is reserved).

PWE: Parameter value (4 bytes).

PKE handling:

b

15

b

14

b

13

b

12

b

11

b

10

b

9

b

8

b

7

b

6

b

5

b

4

b

3

b

2

b

1

b

0

AK

SPM

PNU

Figure 5-1 PCA word

AK: Request/response characteristics (Range 0-15)
SPM: Toggle bit for Spontaneous Messages, not used by SJ-PB(T).
PNU: Parameter number. Range 1- 418 for Hitachi specific parameters and 900-999 for Profidrive specific parameters.
Please refer to chapter 3.5 for which Profidrive specific parameters that are supported.

Advertising