APPENDIX PARAMETER CROSS-REFERENCE LIST

31

Code No. Size

Range

Magn.

Contents

L300P

Read/

Write

d084

376

2

0 1000.0V

*10

PN voltage (DC voltage) of Trip4

RO

d084

377

4

0

4294836225s

*1

Accumulated time during running

of Trip4

RO

d084

378

4

0

4294836225s

*1

Accumulated time during power ON

of Trip4

RO

d085

379

4

00 H'FF

*1

Factor and Status of Trip5

RO

d085

380

4

0 400.00Hz

*100

Frequency of Trip5

RO

d085

381

2

0 1000.0A

*10

Output current of Trip5

RO

d085

382

2

0 1000.0V

*10

PN voltage (DC voltage) of Trip5

RO

d085

383

4

0

4294836225s

*1

Accumulated time during running

of Trip5

RO

d085

384

4

0

4294836225s

*1

Accumulated time during power ON

of Trip5

RO

d086

385

4

00 H'FF

*1

Factor and Status of Trip6

RO

d086

386

4

0 400.00Hz

*100

Frequency of Trip6

RO

d086

387

2

0 1000.0A

*10

Output current of Trip6

RO

d086

388

2

0 1000.0V

*10

PN voltage (DC voltage) of Trip6

RO

d086

389

4

0

4294836225s

*1

Accumulated time during running

of Trip6

RO

d086

390

4

0

4294836225s

*1

Accumulated time during power ON

of Trip6

RO

-

392

1

00 02

code

Selection of Area code of inverter

RO

-

393

1

01 15

code

Selection of Capacity code of inverter

RO

-

394

1

00,01

code

Selection of Voltage of inverter

RO

-

395

1

00,01

code

Selection of Changeover of inverter mode

RO

d001

397

4

0 400.000Hz

*1000

Output frequency

RO

d004

398

4

0 400.000Hz

*1000

Feedback data of PID control

RO

d007

399

4

0 39960.000

*1000

Value of conversion of frequency

RO

d101

400

4

0 400.000Hz

*1000

Output frequency after Vector control

RO

d016

401

4

0

4294836225s

*1

Accumulated time during running

RO

d017

402

4

0

4294836225s

*1

Accumulated time during Power ON

RO

-

403

4

0 400.000Hz

*1000

Setting frequency from terminal

RO

-

404

4

0 400.000Hz

*1000

Setting frequency from

attached potentiometer

RO

-

405

4

0 400.000Hz

*1000

Setting frequency from digital operator

RO

d002

407

2

0 1000.0A

*10

Output current

RO

d005

408

2

0 H'FFFF

bit

Status of Input terminal

RO

d012

409

2

-300 +300%

*1

Output Torque

No

RO

d014

410

2

0 1000.0kW

*10

Input electric power

RO

412

2

0 1000.0V

*10

DC voltage

RO

413

2

0 100.0s

*10

On time of BRD running

RO

414

2

0 100.0%

*10

Used rate of electronics thermal protection

RO

d006

416

2

0 H'FFFF

bit

Status of output terminal

RO

d013

417

2

0 1000.0V

*10

Output voltage

RO

d003

418

1

00 02

code

Direction of present running

RO

R/W: Parameter is read/writable.