1. jump start/battery charge cable connections – Hobart Welding Products POWERPAK OM-478 User Manual

Page 32

Advertising
background image

OM-478 Page 28

SECTION 7 – OPERATING OPTIONAL BATTERY CHARGER

Follow jump starting procedure to quickly start equipment having a weak or dead
battery. Follow charging procedure to trickle-charge a battery.

NOTE

7-1.

Jump Start/Battery Charge Cable Connections

ST-153 653-A

Y

Stop engine.

Y

Do not charge or jump start a
battery which has loose ter-
minals or one showing dam-
age such as a cracked case
or cover.

Y

Have only qualified persons
do battery charging work.

Y

Keep cables away from
moving parts.

Y

Do not use damaged cables.

Y

Read supplied BCI Battery
Service Manual before
charging or jump starting.

1

Jump Start/Battery Charge
Plug

2

Red (+) Cable

3

Black (–) Cable

Obtain cable with proper
connectors.

4

Remote Momentary-On
Switch And Plug

Remote switch is used only for
jump starting a battery. Press
switch to turn jump starting output
on. Release switch to turn output
off.

Open lower access door. Route
cable as shown. Insert plug into
Remote 14 receptacle, and tighten
threaded collar. Close door.

5

Cover

6

Jump Start/Battery Charge
Receptacle

Remove cover, and insert plug in
receptacle. Connect remaining end
of cable to equipment being jump-
started or charged. Use correct
polarity (+ and –) when making con-
nections.

Tools Needed:

3/8 in

1

2

5

6

3

4

Advertising